A method is described for estimating oestriol in 2–10 ml samples of human pregnancy peripheral plasma. It incorporates acid hydrolysis, chemical purification, methylation, chromatography on alumina columns, formation of a derivative and quantitative determination by gas chromatography. A radioactive internal standard was added to correct for procedural losses. Plasma oestriol determinations in five normal patients throughout pregnancy and delivery are reported.
| HOME | HELP | CONTACT US | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |